Installation of pipeline pump

1. The radial beat of the equipment shaft should be less than 0.04 mm, and the axial momentum of the shaft should not be greater than 0.1 mm;

2. The sealing parts of the equipment should be kept clean during installation. The sealing parts shall be cleaned and the sealing end shall be intact, preventing impurities and dust from bringing in the sealing parts;

3. During installation, it is strictly forbidden to touch and knock, so as to prevent the mechanical seal friction from being damaged and seal failure;

4. The surface of the installation shall be coated with a clean mechanical oil to facilitate the installation;

5. When installing the static ring gland, the tightening screw must be evenly distributed to ensure the vertical requirements of the static ring end and axial line.

6. After installation, push the moving ring with the hand to make the moving ring move flexibly on the axle and have some flexibility;

7. After installation, the rotation axis and rotation axis should be of no weight;

8. The equipment must be filled with media before operation to prevent dry friction and seal failure;